Surface Temperature Sensor Measurement for Pipeline

Product Details
Customization: Available
Installation Type: Tee Type
Sensing Type: Resistive
Still deciding? Get samples of US$ 1/Piece
Request Sample
Gold Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
4200 square meters
  • Surface Temperature Sensor Measurement for Pipeline
  • Surface Temperature Sensor Measurement for Pipeline
  • Surface Temperature Sensor Measurement for Pipeline
  • Surface Temperature Sensor Measurement for Pipeline
  • Surface Temperature Sensor Measurement for Pipeline
  • Surface Temperature Sensor Measurement for Pipeline
Find Similar Products

Basic Info.

Model NO.
TSP Series
Output Signal Type
Analog Type
Production Process
Normal Wirewound
Material
PT1000/ PT100
Measuring Medium
Temperature
IP Rating
IP67
Certification
CE
Customized
Customized
Housing Material
SUS304
Temperature Range
-20~150ºC
Accuracy
1%
Transport Package
Standard Export Package
Trademark
Yuanben
Origin
Shanghai
HS Code
9033000000
Production Capacity
500, 000PCS/Year

Product Description

Surface Temperature Sensor Measurement with Clamp-on Technology
       Measuring the medium temperature is a common task in the pharmaceutical and food industry. This is usually achieved with invasive measuring systems which reach into the process area. This procedure is common and robust, but the necessary process interfaces add an additional hygienic risk.
       An alternative way especially for the measurement of steam sterilisation is by measuring the pipe surface temperature. The surface measurement method is more sensitive to process and ambient conditions. The measuring insert is suited with an especially fast operating silver temperature sensor. Constant pressure is applied to the surface of the pipe by the spring force. It is particularly useful for measuring water and watery solutions, as well as saturated steam in indoor applications. yuanben´s clamp-on devices for surface measurements are convincing by quick and cost efficient installation without welding.
      The common method of steam sterilisation requires usually the sterilisation temperature to be monitored at various locations in the system. In this cases the advantages of surface temperature measurement, i.e. lower system costs and more flexibility, can be fully utilized.


      Thermal resistance temperature detection sensor for pipeline surface, is a non probe type temperature measurement sensor. The thermistor temperature sensor can be refitted to the existing pipeline at any time without disconnecting or interrupting the circuit. Its measurement range is - 20 ° C to + 150 ° C. The measuring core can be fixed to the pipe through the pipe joint. The measuring probe is spring loaded and the silicone rubber lining of the pipe joint separates the top of the sensor from the ambient temperature. The output mode of the thermistor temperature sensor can be directly selected and used as a transmitter. The product is small and compact, designed for operation in applications with limited installation space. If necessary, the measuring probe can be removed for calibration. All electrical components are moisture proof (IP67). Users can choose the connection method of process connection and sensor according to the actual application. The electrical connection is made through the M12 round connector.


Features
No need to probe into the pipeline, compact design to save installation space, the electrical connector of M12 is simple and fast, the measuring probe can be disassembled and calibrated, and the protection structure design can reduce the ouside influence on the pipeline temperature.

Applications
Health industry, food and beverage industry, biopharmaceutical industry, special pipeline temperature detection


Specifications
Temperature range -20~150ºC
Connection Two wire type(resistance output);2 wire type (current output)
Accuracy ±1%
Analog Output Resistance or current output
Power Supply Vcc 9-30Vdc(curren output)
Response Time <10s
Activation Delay, Electrical 1s
False Signal Current >23mA
Electrical Connection M12 electrical connector 4 Pin
Circuit Protection Short Circuit Protection
Electromagnetic Compatibility(EMC) Comply with EN61326
Ambient Temperature Range --20-85ºC
Humidity max. Comply with IEC 60068-2-30 var. 2 standard
Ingress Protection IP67
Pipe Diameter Dia.16~30 selectable, other sizes can be customized
Housing Material Stainless Steel SUS304

Photos
Surface Temperature Sensor Measurement for PipelineSurface Temperature Sensor Measurement for PipelineSurface Temperature Sensor Measurement for PipelineSurface Temperature Sensor Measurement for Pipeline

Surface Temperature Sensor Measurement for Pipeline
Surface Temperature Sensor Measurement for Pipeline
Surface Temperature Sensor Measurement for Pipeline


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier