Customization: | Available |
---|---|
Type: | Magnetic Displacement Sensor |
Output Signal Type: | Digital Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
RFSS series non-contact safety switch is a safety switch based on RFID technology designed for safety circuits. Compared with mechanical switches or magnetic switches, it has higher detection confidentiality, strong anti-interference, safety and reliability. Built-in codec device, with three different encoding modes (standard, independent, unique independent) can be the best way, with tamper-proof performance, can effectively prevent missing or false positives, or artificial abnormal trigger. Security dual channel output technology security level performance up to PLe/SIL3, in line with international standards (EN ISO 13849-1) (EN 62061), can be applied to mobile protection devices (e.g. security door monitoring, cover and valve protection, security locks) position monitoring, to prevent unauthorized entry, It is used to avoid personnel from being injured by dangerous sports, or affecting and interfering with the production process and other high-risk occasions that need to be strictly monitored or prevented. Achieve IP67 or IP69K protection and can be used in harsh equipment environments. Using composite engineering plastic shell material, it has the characteristics of easy cleaning and long service life. The M12 interface enables rapid system integration.
Ii. Characteristics
complies with international standards such as (EN ISO 13849-1) (EN 62061)
The safety level is PLe /SIL3
RFID-based technology with tamper-proof performance, with three different encoding modes
Achieved IP67 and IP69K protection grades for use in harsh equipment environments
2 m or 150mm long cable with M12 interface for rapid system integration
PBT or PA engineering plastic housing materials for easy cleaning and long service life
strong anti-interference, safe and reliable
Safety level
Standard ISO13849-1, IEC/EN60947-5-3, EN 62061
The security classification conforms to ISO13849-1 Cat4 / SIL3, and the dual-channel interlock can reach PLe
Technical parameter
Safe output 2X PNP normally on
Auxiliary output 1X PNP normally closed (non-secure output)
Working distance conduction. Min: 15mm;
Safe output current 200mA
Operating voltage 24VDC±15%
Working current 50mA
Response time 50ms
Protection class IP67 (potting process to be verified)
Operating frequency 10 Hz (required no)
Operating temperature -10~+60ºC
Relative humidity 5... 95%
Shell material PBT or PA