TST-03 temperature transmitter is the high performance temperature transmitter that accepts RTD (Pt100, Pt1000), inputs and converts it to a 4 to 20 mA DC or 0 to 5 V DC signal for transmission. Integrative metal housing structrue, local LCD display can be selected. Features High performance: Micro-processor-based sensing technology ensures long-term accuracy and high reliability. High reliability: Dual-compartment housing realizes high resistance capability to harsh environments, Variety of sensor inputs: The type of sensor input is user-selectable from RTD (Pt100, Pt1000)
Item |
Technical Parameter |
Supply Voltage |
12 VDC |
Output Signal |
4-20mA; 0-5V, 0.5-4.5V |
Input Signal |
Pt100; Pt1000 temperature sensor |
Rating Power |
Less 0.6w |
Load Resistance |
Less 500Ω,more 3KΩ |
Humidity |
Less 90% RH at 40ºC |
Accuracy |
±0.3%;±0.5% or ±1.0% |
Stability |
≤0.2% FS |
Operating Temp |
0-85ºC |
Mounting Threads |
3/4NPT; G1/2;M16 |
Electrical Connection |
A1 case or Can be customized |
Sealing Rating |
IP65 |
The Inference of Ambient Temp.Variable |
0.2% CLASS, 0.02% FS/ºC |
0.5% CLASS, 0.05% FS/ºC |
1.0% CLASS, 0.05% FS/ºC |
|
|
Typical Technical Specifications
Performance Specifications
Accuracy: ± 0.1 % of calibrated span
Ambient Temperature Effect (per 10 °C change): ± 0.1 %
Stability: RTD: ± 0.1% of reading
2 Year Stability: RTD: ± 0.2% of reading.
Power Supply Effect: ±0.005 % of calibration span per volt
Vibration Effect: 10 to 60 Hz 0.21 mm peak displacement, 60 to 2000 Hz 3G
Functional Specifications
Input: Input type is selectable: 2-, 3-, and 4-wire RTD,
Span & Range Limits:
Input lead wire resistance (for RTD): 10 Ohms per wire or lower
Output: Two wire 4 to 20 mA DC.
Isolation: Input/Output/GND isolated to 500 V DC
Sensor Burnout: High (21.6 mA DC) or Low (3.6 mA DC), user selectable.
Output in Transmitter Failure: Up-scale: 110%, 21.6 mA DC or more Down-scale: -5%, 3.2 mA DC or less
Update Time: Approximately 0.5 seconds
Turn-on Time: Approximately 5 seconds
Damping Time Constant: Selectable from 0 to 99 seconds
Ambient Temperature Limits: Option code may affect limits.
-40 to 85 °C (-40 to 185 °F)
-30 to 80 °C (-22 to 176 °F) with Integral Indicator
Ambient Humidity Limits: 5 to 100 % RH at 40 °C (104 °F)
Supply & Load Requirements:
Supply Voltage:
10.5 to 42 V DC for general use and flameproof type
10.5 to 32 CV DC for lightning protector (Optional code /A)
Load: 0 to 1335 Ohms for operation, and 250 to 600 Ohms for digital communication
Physical Specifications
Enclosure
Material: Low copper cast-aluminum alloy
Degrees of Protection: IP67,
Mounting: Optional mounting brackets can be used either for two-inch pipe or flat panel mounting.
Terminal Screws: M4 screws
Integral Indicator: Optional LCD digital indicator includes 5-digit numerical display with °C.