The Magnetic guiding sensor developed by Yuanben, has a special made magnetic position sensor used to find small magnetic field (a magneic path is installed in the floor), and to keep the AGV heading direction continuously under control. The magnetic guidance sensors give signal about the AGV position deviations as the AGV passed the magnetic path, provides an output voltage proportional to the rate of turn at its magnetic path centre axis.
Magnetic guidance path can easily be installed in wood floors and other types of environment not well suited for guide wire installation.
Product Model |
MGS-H-S-2-C20 |
Product Number |
MGS-H16 |
Material Of Housing |
Aluminum Case |
Supply voltage |
+24 VDC ±5%, ripple (p-p) 1% max. |
Power consumption |
35mA max. (at DC+24V) |
70mA max. (at DC+12V) |
75mA max. (at DC+5V) |
Digital type Output |
NPN Transistor Open Collector
Normally open
Applicable voltage 30V max.
Sink current 100mA max. |
Operation Temperature |
-10ºC to +50ºC (Non-freezing) |
Operation Humidity |
35 to 95%RH (Non-condensing) |
Prevent Class |
IP65 |
Storage Temperature |
from -30 to +80ºC |
Storage Humidity |
from 35% to 95%RH (no condensation) |
Target |
MGT-50 -25 series magnetic guide tape |
Operation Air Gap |
30 to 40mm (standard MGT-50-25) |
Sensitivity |
N-pole;6mT and over/ S-pole; 6mT and over |
Element |
16 bits |
Pitch |
10mm at even intervals |
Logic |
Normally open |
Circuit |
NPN open collector (DC30V, 50mA max.) |
Residual voltage |
2V max. (at 50mA) |
Response |
1ms |
Insulation Resistance |
50MOhm |
Connector |
MIL-C-83503, 20Pin |
Prevent circuit |
Over-voltage and short circuit and reverse polarity protection |
Mounting |
Both Centre axis line of magnetic tape and sensor is Coincide |
Appliance |
AGV |