Customization: | Available |
---|---|
Type: | Network Type |
Measuring Medium: | Temperature |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Input | 2-,or 3-wire 100 ohm platinum or 3-wire 5 ohm copper RTD's. |
2.Output | 4 to 20 mA DC over specified range. |
3.Accuracy | +/- 0.1% of span. |
4.Linearity | +/-0.1% of span. |
5.Adjustments | Zero and Span:+/- 5% of span, non-interacting. |
6.Ambient Temperature | |
7.Operating | -40 to 85ºC(-40 to 185°F) |
8.Storage | -55 to 100ºC (-67 to 212°F) |
9.Ambient Temperature Effects | +/- 0.005% of span/°F(+/- 0.009% of span/ºC). |
10.Double specification for spans | < 10 ohms. |
11.Warm-up Drift | +/- 0.1% of span max.(assuming V supply=24 VDC and Rloop=250 ohms.Stable within 15 minutes.) |
12.Supply Voltage | 10 to 35 volts DC with no load.Reverse polarity protected. |
13.Voltage effect | +/- 0.001% of span per volt. |
14.Lead wire Compensation(3-wire RTD) | +/-0.05@ of span per ohm,up to 25 ohms in each leg. |
15.Maximum Load Resistance | The maximum allowable resistance of the signal-carrying loop is given by this formula: Rloop max=(Vsupply-10)/0.02 amps. |
16.Minimum Output current | 2.2mA. |
17.Maximum Output current | 28mA. |
18.Connections | Terminal blocks accept wires from AWG 22 to AWG 14. |
19.Physical | Epoxy potted for moisture resistance. |