Customization: | Available |
---|---|
Type: | Magnetic Displacement Sensor |
Output Signal Type: | Analog Type |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Characteristic | RADS series (Low Voltage) |
Supply voltage | 5 ±0.5 Vdc |
Supply current: Normal | 20 mA max. |
During output to ground short | 25 mA max. |
Output: standard | 0.5 Vdc to 4.5 Vdc Ratio-metric |
inverted | 4.5 Vdc to 0.5 Vdc Ratio-metric |
Output signal delay | 4 ms typ. |
Reverse polarity protection | -10 Vdc |
Overvoltage protection | 10 Vdc |
Output to ground short circuit | continuous |
Resolution | 12 bit |
Output load resistance (pull down to ground) | 10 kOhm typ. |
EMI: radiated immunity | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz |
EMI: conducted immunity | 100 mA BCI per ISO11452-4, from 1 MHz to 200 MHz |
Characteristic | RADS Series (Low Voltage) |
Expected life | infinite rotation |
Air gap: bare magnet actuator | 3,00 mm ±0.5 mm [0.12 in ±0.02 in] |
Air gap: housed magnet actuator | 2,00 mm ±0.5 mm [0.08 in ±0.02 in] |
misalignment | 2.002,00 mm [0.08 in] max. |
Material: | |
magnet | NdFeB |
sensor housing | PBT plastic |
housed magnet over-mold sensor/ | PPS plastic |
housed magnet bushing sensor bushing | brass |
Mating connector | AMP Super-seal 282087-1 |
Mechanical end stop | no |
mounting screw sizes: sensor to mounting surface |
non-magnetic, stainless steel M4 X 0.7 screws and 8 mm [0.31 in] OD washers |
housed magnet actuator to actuator mounting shaft |
non-magnetic, stainless steel M3 X 0.5 plain cup point set screws |
Approvals | CE |
Characteristic | RADS Series (Low Voltage) |
Operating temperature range | -40 °C to 125 °C [-40 °F to 257 °F] |
Ingress protection | IP69K |
Media compatibility | heavy transportation fluids |
Shock1 | 50 G peak |
Vibration1 | 20 G peak |
Salt fog | bare magnet: 96 hr for as per ASTM B117 |
housed magnet: 240 hr per ASTM B117 |
Actuator Type | Series | Actuator Type |
Integral shaft without lever | Separate bare magnet |