Customization: | Available |
---|---|
Type: | Magnetic Displacement Sensor |
Output Signal Type: | Analog Type |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | a | b | c |
Polarity reversal protection | yes | ||
Output signal | 4 mA-20 mA | 0.5 V DC-4.5 V DC | |
Output signal central position/zero position | 12 mA | 2.5 V DC | |
Resolution | 0.1 ° | ||
Operating voltage | 10 -30V DC | 4.5-5.5VDC | 10-30Vdc |
Current consumption | 18 mA | 8 mA | 18 mA |
Load resistance | 250Ω | 2KΩ | |
Short-circuit resistance to supply | yes | ||
Short-circuit resistance to GND | yes | ||
Temperature coefficient | typ. ±250 ppm/K | ||
Signal sequence | Standard CCW (optional CW) | ||
Signal update rate | 2000 Hz | ||
Outputs (quantity, type) | 1 | ||
Testing Technology | Hall effect | ||
Angle measuring range | 30°...120 ° | ||
Outputs | 4...20mA | 0,5...4,5V ratio-metric | 0,5...4,5V |
MTTF | 101 a | 225.7 a | 133 a |
EMC Agricultural and forestry machines (Norm) | EN ISO 14982 pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 |
EN ISO 14982 conducted disturbance not applicable for 5V supply |
EN ISO 14982 pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 |
EMC Earth-moving and building construction machinery (Norm) | DIN EN ISO 13766-1 pulse "load dump": max. voltage 35V (absolute) |
DIN EN ISO 13766-1 conducted disturbance not applicable for 5V supply |
DIN EN ISO 13766-1 pulse "load dump": max. voltage 35V (absolute) |
EMC Industrial trucks (Norm) | DIN EN 12895 | ||
Typical linearity error | <= ±15° : ±0,2°;<= ±25° : ±0,4°,<= ±35° : ±1,0°;<= ±45° : ±2,0°;<= ±60° : ±5,0° |