General technical data: |
|
Design of the operating mechanism |
Code magnet |
Product function / cross circuit/short circuit recognition |
YES |
Product function / positive opening |
No |
Operating voltage / rated value |
24V dc |
Operating current / rated value |
100mA |
Suitability for use / safety-related circuits |
yes |
Switching frequency Hz |
5 |
Secure switching distance ON |
17mm |
Secure switching distance OFF |
8m |
Design of the evaluation unit / required |
YES |
Reference code / according to DIN 40719 extended according to IEC 204-2 / according to IEC 750 |
S |
Reference code / according to DIN EN 61346-2 |
S |
Enclosure: |
|
Mounting type |
screw fixing |
Design of the housing |
blue |
Material of the enclosure |
plastic of the cable sheath |
PVC plastic of the active sensor area |
|
Height of the sensor mm |
13 |
Length of the sensor mm |
36 |
Width of the sensor mm |
26 |
Mechanical installation condition for sensor |
no flush installation possible |
Contact: |
|
Design of the contact element |
reed switches |
Design of the switching function |
NC contact and NO contact |
Number of NC contacts / for auxiliary contacts |
2 |
Number of NO contacts / for auxiliary contacts |
0 |
Number of changeover contacts / for auxiliary contacts |
0 |
Design of the electrical connection cable |
3m |
Design of the switching output |
contacts |
Ambient conditions: |
|
during operating |
-25 … +70 °C |
during storage and transport |
-25 … +70 °C |
Shock resistance / according to IEC 60068-2-27 |
Sinusoidal half-wave 30g / 11 ms |
Resistance against vibration / according to IEC 60068-2-6 |
10 ... 55 Hz: 1 mm |
Certificates/ approvals: |
|
Protection class IP |
IP67 |
Verification of suitability |
CE |
Safety Integrity Level (SIL) / according to IEC 61508 |
SIL3 |
Performance level (PL) / according to EN ISO 13849-1 |
e |
Category / according to EN 954-1 |
4 |