The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification

Product Details
Customization: Available
Type: Microwave Sensor Switch
Application: Warehouse
Still deciding? Get samples of US$ 1/Piece
Request Sample
Gold Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
4200 square meters
  • The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
  • The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
  • The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
  • The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
  • The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
Find Similar Products

Basic Info.

Model NO.
RFSS-1015
Certification
ISO, RoHS, CE
Transport Package
Carton
Trademark
Yuanben
Origin
Shanghai
HS Code
85299050
Production Capacity
50, 000PCS/Year

Product Description

Description
Technology (RFID) in a variety of housings. Unlike other RFID switches on the market that use OSSD, Fortress have made the FR range standalone by adding volt free contacts. This means you are free to use most safety relays on the market, and not those specified to work with OSSD only.

The non-contact operation makes these safety switches easy to install and tolerant to misalignment. They are individually coded for high security applications providing a simple reliable solution to machine guard interlocking.

A risk assessment should take place to establish that the specifications of these safety switches are suitable for the application required.

Application
Can used in forming and filling (aluminum steel and plastic)
Pick and place packaging equipment
Pick and place/assembly equipment
Semi-conduction equipment
Plastic molding equipment
Woodworking machinery
Textile machinery
Printing machinery


Specifications
Technical Specifications RFSS-1015 FRSS-1015A
Contacts 2 NO + 1 NC 2 NO + 1 NC
     
Supply Voltage Options 24VDC (+/- 15%) 24VDC (+/- 15%)
     
Safety Contact Rating 24VDC / 500mA 24VDC / 3 Amps
     
Safety Contact Switching 10mm ON / 15mm OFF 10mm ON / 15mm OFF
     
Auxiliary Contact Rating 24VDC / 500mA 24VDC / 3 Amps
     
Auxiliary Contact Switching 10mm ON / 15mm OFF 10mm ON / 15mm OFF
     
External Fuse (customer supplied) 300mA Fast Acting 2.5 Amps Fast Acting
     
Construction Orange ABS Orange ABS
     
IP Rating IP67/IP69K IP67/IP69K
     
Operating Temperature -10°C to +60°C -10°C to +60°C
     
Fixing 4 X M4 Security Screws 4 X M4 Security Screws
     
Connection Pre-Wired or M12 QD Pre-Wired or M12 QD
     
Coding Individually Coded Individually Coded
     
Indication Dual Color LED Dual Color LED
     


Safety Related Data
B10d 2,000,000 PFH 6.52 x 10-8
       
TM (Mission Time) > 30 Years PFHd 4.3 x 10-8 See Note 1
       
DC 99% SFF 99%
       
MTTFd High > 100 Years (Based on usage rate of 360 Days/Year, 24 Hours/Day, 10 Operations/Hour)
       
Note 1: Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years. Suitable for performance level applications PLe according to ISO 13849-1. (SIL 3 or SIL 2 according to IEC 62061)
 
Approvals CE Complies with all relevant sections of the CE Marking Directive
cUL 508 Industrial Control, TUV Approved
International Directives Machinery Directive 2006/42/EC, Low Voltage Directive 2014/35/EU; EMC Directive 2014/30/EU, RoHS Directive 2011/65/EC
  BS EN 12100 Safety of Machinery. General principles for design.
International Standards BS EN ISO 14119 Safety of Machinery. Interlocking devices associated with guards. Principles for design and selection.
BS EN ISO 13849 Safety of Machinery. Safety related parts of control systems.
BS EN ISO 62061 Safety of Machinery. Functional safety of safety related electrical, electronic and programmable electronic control
systems
  BS EN 60204 Safety of Machinery. Electrical equipment of machines.
BS EN 60947-5-1 Low-voltage switchgear and control gear.
BS EN 60947-5-3 Low-voltage switchgear and control gear.
   

Dimension
The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
Mounting
The FR range of safety switches can approach each other from most angles. When the guard is closed the targets on the printed face of the switch and actuator must be aligned.

Mount the switch on to the machine frame and the actuator on to the opening edge of the door.

Use the tamper proof screws provided to make the installation more secure.

Do not use the safety switch as a door stop. Leave a minimum of 50 mm between any adjacent switches.

EN 14119

Provides some mounting suggestions, see example opposite.
The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification
Connections & Fuses
The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency IdentificationSwitching Characteristics
The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification

Picture and Dimension

The Rfss-1015 No Contact RFID Safety Switches with Radio Frequency Identification

















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier