Item | Test condition | Minimum value | Typical value | Maximum value | Unit | ||
Operating Parameters | Operating voltage | Direct Current | 8 | 12 | 30 | V | |
Static operating current | VCC=12V(non-loaded) | 15 | 20 | 25 | mA | ||
Operating temperature | -40 | +85 | ºC | ||||
Performance parameters | Measurement range | Dual Axis | ±10,±30,±80,±90 | deg | |||
(1 Resolution | Measuring range ≤±90 | 0.01,0.05,0.1 | deg | ||||
(2 Accuracy | Measuring range ≤±10 |
Resolution :0.01 | +0.05 | ±0.1 | deg | ||
Resolution :0.1 | ±0.2 | ±0.3 | |||||
Measuring range ≤±30 |
Resolution :0.01 | ±0.1 | 0.2 | deg | |||
Resolution :0.1 | +0.3 | ±0.4 | |||||
Measuring rang e ≤±60 |
Resolution :0.01 | +0.15 | ±0.3 | deg | |||
Resolution :0.1 | ±0.4 | ±0.5 | |||||
Measuring range ≤±80 |
Resolution :0.01 | ±0.4 | ±0.8 | deg | |||
Resolution :0.1 | ±0.8 | ±1 | |||||
±80<measuring range ≤±90 | ±5 | ±10 | deg | ||||
Repeatability | Measuring range ≤±10 |
Resolution:0.01 | ±0.04 | deg | |||
Resolution:0.05 | ±0.1 | ||||||
Resolution:0.1 | ±0.2 | ||||||
Measuring range ≤±30 |
Resolution:0.01 | 0.06 | deg | ||||
Resolution:0.1 | ±0.25 | ||||||
Measuring range ≤±60 |
Resolution:0.01 | ±0.1 | deg | ||||
Resolution:0.1 | ±0.35 | ||||||
Measuring range ≤±80 |
Resolution:0.01 | ±0.2 | deg | ||||
Resolution:0.1 | ±0.5 | ||||||
Measuring range ≤±90 | ±4 | ±8 | deg | ||||
Zero position temperature drift (3 | -40---+85ºC | 0.005 | 0.01 | °/ºC | |||
Other parameters | Stock temperature | -40 | +85 | ºC | |||
Zero point | 0.3 | deg |